| Syringe Pumps |
 |
| SN-50C6 Syringe Pump |
|
International standard syringe pump
- Compatible: Automatic syringe calibration, suitable for all brands
- Convenient: “Openable slider hook”, convenient to clamp syringe plunger
- Powerful: Battery capable to support more than 6 hours for one channel continuous working
|
|
|
|
Specify syringe size automatically
Identify syringe size automatically
3-level occlusion alarm limits setting
Automatically reduce impact dose release after occlusion
Limits setting
Delivered volume inquiry
KVO flow rate |
|
Fast rate control
“Purge” button activate safe protection
Flow rate setting button lock
Abundant optic and sound alarm
AC and internal power indication
Standard RS232 interface
500 history records |
|
|
| |
SPECIFICATION (Single Channel) |
| Syringes |
10, 20, 30, 50 mL of calibrated syringes |
| Flow rate |
0.1-1500 mL/h (0.1 mL/h step) |
50 mL syringe |
| 0.1-900 mL/h (0.1 mL/h step) |
30 mL syringe |
| 0.1-600 mL/h (0.1 mL/h step) |
20 mL syringe |
| 0.1-400 mL/h (0.1 mL/h step) |
10 mL syringe |
| Purge rate |
1500 mL/h |
50 mL syringe |
| 900 mL/h |
30 mL syringe |
| 600 mL/h |
20 mL syringe |
| 400 mL/h |
10 mL syringe |
Accuracy of flow rate
(Nominal value) |
Accuracy including syringe: within ±2%
Mechanical accuracy: within ±1% |
| Display range of volume delivered |
0.1–9999 mL
(0.1–999.9 mL,0.1mL step)
(1000–9999 mL,1mL step) |
| Setting of delivery limit |
0.1–9999 mL
(0.1–999.9 mL,0.1mL step)
(1000–9999 mL,1mL step) |
| Occlusion detection pressure |
'H': 800±200 mmHg (106.7±26.7 kPa) or 1.09±0.27 kgf/cm2
'C': 500±100 mmHg (66.7±13.3 kPa) or 0.68±0.13 kgf/cm2
'L': 300±100 mmHg (40.7±13.3 kPa) or 0.41±0.13 kgf/cm2 |
Power |
AC110~220V ±10%, 50~60 Hz ±1 Hz
Inner NiMH battery: DC12 V |
| Operation conditions |
Ambient temperature: 5 to 40, Relative humidity: 20% to 80% |
| Storage conditions |
Ambient temperature: -40 to 55, Relative humidity: ≤ 95% |
| Electric shock protection/class |
Class I and internal power supply: Type CF, Continuous operation |
| Water proof level |
IPX4 |
| Weight |
2.25kg (with clamp base) |
| Dimension |
306mm (Width)×135mm (Height)×127mm (Depth) |
|
|
 |
|
|
 |
| SN-50C6T Syringe Pump |
|
International standard syringe pump
- Compatible: Automatic syringe calibration, suitable for all brands
- Convenient: “Openable slider hook”, convenient to clamp syringe plunger
- Powerful: Battery capable to support more than 6 hours for one channel continuous working
- Energy saving: Idle channel can be set to sleeping mode
|
|
|
|
Body weight mode input
Specify syringe size automatically
Identify syringe size automatically
3-level occlusion alarm limits setting
Automatically reduce impact dose release after occlusion
Limits setting
Delivered volume inquiry
KVO flow rate |
|
Operation error prompt
Fast rate control
“Purge” button activate safe protection
Flow rate setting button lock
Abundant optic and sound alarm
AC and internal power indication
Standard RS232 interface
500 history records |
|
|
| |
SPECIFICATION (Single Channel, Body Weight Mode) |
| Syringes |
10, 20, 30, 50 mL of calibrated syringes |
| Flow rate |
0.1-1500 mL/h (0.1 mL/h step) |
50 mL syringe |
| 0.1-900 mL/h (0.1 mL/h step) |
30 mL syringe |
| 0.1-600 mL/h (0.1 mL/h step) |
20 mL syringe |
| 0.1-400 mL/h (0.1 mL/h step) |
10 mL syringe |
| Purge rate |
1500 mL/h |
50 mL syringe |
| 900 mL/h |
30 mL syringe |
| 600 mL/h |
20 mL syringe |
| 400 mL/h |
10 mL syringe |
Accuracy of flow rate
(Nominal value) |
Accuracy including syringe: within ±2%
Mechanical accuracy: within ±1% |
| Display range of volume delivered |
0.1–9999 mL
(0.1–999.9 mL,0.1mL step)
(1000–9999 mL,1mL step) |
| Setting of delivery limit |
0.1–9999 mL
(0.1–999.9 mL,0.1mL step)
(1000–9999 mL,1mL step) |
| Occlusion detection pressure |
'H': 800±200 mmHg (106.7±26.7 kPa) or 1.09±0.27 kgf/cm2
'C': 500±100 mmHg (66.7±13.3 kPa) or 0.68±0.13 kgf/cm2
'L': 300±100 mmHg (40.7±13.3 kPa) or 0.41±0.13 kgf/cm2 |
Power |
AC110~220V ±10%, 50~60 Hz ±1 Hz
Inner NiMH battery: DC12 V |
| Operation conditions |
Ambient temperature: 5 to 40, Relative humidity: 20% to 80% |
| Storage conditions |
Ambient temperature: -40 to 55, Relative humidity: ≤ 95% |
| Electric shock protection/class |
Class I and internal power supply: Type CF, Continuous operation |
| Water proof level |
IPX4 |
| Weight |
2.25kg (with clamp base) |
| Dimension |
306mm (Width)×135mm (Height)×127mm (Depth) |
|
|
 |
|
|
 |
| SN-50F6 syringe pump |
|
International standard syringe pump
- Compatible: Automatic syringe calibration, suitable for all brands
- Convenient: “Openable slider hook”, convenient to clamp syringe plunger
- Powerful: Battery capable to support more than 6 hours for one channel continuous working
- Energy saving: Idle channel can be set to sleeping mode.
|
|
|
|
Dual-channel with different flow rate
Channel sleeping function
Identify syringe size automatically
3-level occlusion alarm limits setting
Limits setting
Automatically reduce impact dose release after occlusion
Delivered volume inquiry
KVO flow rate |
|
Operation error prompt
Fast rate control
"Purge" button activate safe protection
Flow rate setting button lock
Abundant optic and sound alarm
AC and internal power indication
Standard RS232 interface
500 history records |
|
|
| |
| SPECIFICATION (Dual Channel) |
| Syringes |
10, 20, 30, 50 mL of calibrated syringes |
| Flow rate |
0.1-1500 mL/h (0.1 mL/h step) |
50 mL syringe |
| 0.1-900 mL/h (0.1 mL/h step) |
30 mL syringe |
| 0.1-600 mL/h (0.1 mL/h step) |
20 mL syringe |
| 0.1-400 mL/h (0.1 mL/h step) |
10 mL syringe |
| Purge rate |
1500 mL/h |
50 mL syringe |
| 900 mL/h |
30 mL syringe |
| 600 mL/h |
20 mL syringe |
| 400 mL/h |
10 mL syringe |
Accuracy of flow rate
(Nominal value) |
Accuracy including syringe: within ±2%
Mechanical accuracy: within ±1% |
| Display range of volume delivered |
0.1–9999 mL
(0.1–999.9 mL,0.1mL step)
(1000–9999 mL,1mL step) |
| Setting of delivery limit |
0.1–9999 mL
(0.1–999.9 mL,0.1mL step)
(1000–9999 mL,1mL step) |
| Occlusion detection pressure |
'H': 800±200 mmHg (106.7±26.7 kPa) or 1.09±0.27 kgf/cm2
'C': 500±100 mmHg (66.7±13.3 kPa) or 0.68±0.13 kgf/cm2
'L': 300±100 mmHg (40.7±13.3 kPa) or 0.41±0.13 kgf/cm2 |
Power |
AC110~220V ±10%, 50~60 Hz ±1 Hz
Inner NiMH battery: DC12 V |
| Operation conditions |
Ambient temperature: 5 to 40, Relative humidity: 20% to 80% |
| Storage conditions |
Ambient temperature: -40 to 55, Relative humidity: ≤ 95% |
| Electric shock protection/class |
Class I and internal power supply: Type CF, Continuous operation |
| Water proof level |
IPX4 |
| Weight |
3.45kg (with clamp base) |
| Dimension |
354mm (Width)×190mm (Height)×128mm (Depth) |
|
|
 |
|
|
 |
| SN-50T66 |
|
International standard syringe pump
- Compatible: Automatic syringe calibration, suitable for all brands
- Convenient: “Openable slider hook”, convenient to clamp syringe plunger
|
|
|
|
Triple channel with different flow rate
Channel sleeping function
Syringe calibrate automatically
Identify syringe size automatically
3-level occlusion alarm limits setting
Automatically reduce impact dose release after occlusion
Limits setting
Delivered volume inquiry
Wireless communication (Optional) |
|
KVO flow rate
Fast rate control
“Purge” button activate safe protection
Flow rate setting button lock
Abundant optic and sound alarm
AC and internal power indication
Standard RS232 interface
500 history records
Operation error prompt
|
|
|
| |
| SPECIFICATION (Triple Channel) |
| Syringes |
10, 20, 30, 50 mL of calibrated syringes |
| Flow rate |
0.1-1500 mL/h (0.1 mL/h step) |
50 mL syringe |
| 0.1-900 mL/h (0.1 mL/h step) |
30 mL syringe |
| 0.1-600 mL/h (0.1 mL/h step) |
20 mL syringe |
| 0.1-400 mL/h (0.1 mL/h step) |
10 mL syringe |
| Purge rate |
1500 mL/h |
50 mL syringe |
| 900 mL/h |
30 mL syringe |
| 600 mL/h |
20 mL syringe |
| 400 mL/h |
10 mL syringe |
Accuracy of flow rate
(Nominal value) |
Accuracy including syringe: within ±2%
Mechanical accuracy: within ±1% |
| Display range of volume delivered |
0.1–9999 mL
(0.1–999.9 mL,0.1mL step)
(1000–9999 mL,1mL step) |
| Setting of delivery limit |
0.1–9999 mL
(0.1–999.9 mL,0.1mL step)
(1000–9999 mL,1mL step) |
| Occlusion detection pressure |
'H': 800±200 mmHg (106.7±26.7 kPa) or 1.09±0.27 kgf/cm2
'C': 500±100 mmHg (66.7±13.3 kPa) or 0.68±0.13 kgf/cm2
'L': 300±100 mmHg (40.7±13.3 kPa) or 0.41±0.13 kgf/cm2 |
Power |
AC110~220V ±10%, 50~60 Hz ±1 Hz
Inner NiMH battery: DC12 V |
| Operation conditions |
Ambient temperature: 5 to 40, Relative humidity: 20% to 80% |
| Storage conditions |
Ambient temperature: -40 to 55, Relative humidity: ≤ 95% |
| Electric shock protection/class |
Class I and internal power supply: Type CF, Continuous operation |
| Water proof level |
IPX4 |
| Weight |
5.4kg (with clamp base) |
| Dimension |