Vital Bio Systems Logo
 
 
 
Syringe Pumps
SN-50C6 Syringe Pump
Arul International standard syringe pump
  • Compatible: Automatic syringe calibration, suitable for all brands
  • Convenient: “Openable slider hook”, convenient to clamp syringe plunger
  • Powerful: Battery capable to support more than 6 hours for one channel continuous working

Function

Specify syringe size automatically
Identify syringe size automatically
3-level occlusion alarm limits setting
Automatically reduce impact dose release after occlusion
Limits setting
Delivered volume inquiry
KVO flow rate

Fast rate control
“Purge” button activate safe protection
Flow rate setting button lock
Abundant optic and sound alarm
AC and internal power indication
Standard RS232 interface
500 history records
 

SPECIFICATION (Single Channel)

Syringes
10, 20, 30, 50 mL of calibrated syringes
Flow rate 0.1-1500 mL/h (0.1 mL/h step) 50 mL syringe
0.1-900 mL/h (0.1 mL/h step) 30 mL syringe
0.1-600 mL/h (0.1 mL/h step) 20 mL syringe
0.1-400 mL/h (0.1 mL/h step) 10 mL syringe
Purge rate 1500 mL/h 50 mL syringe
900 mL/h 30 mL syringe
600 mL/h 20 mL syringe
400 mL/h 10 mL syringe
Accuracy of flow rate
(Nominal value)
Accuracy including syringe: within ±2%
Mechanical accuracy: within ±1%
Display range of volume delivered 0.1–9999 mL
(0.1–999.9 mL,0.1mL step)
(1000–9999 mL,1mL step)
Setting of delivery limit 0.1–9999 mL
(0.1–999.9 mL,0.1mL step)
(1000–9999 mL,1mL step)
Occlusion detection pressure 'H': 800±200 mmHg (106.7±26.7 kPa) or 1.09±0.27 kgf/cm2
'C': 500±100 mmHg (66.7±13.3 kPa) or 0.68±0.13 kgf/cm2
'L': 300±100 mmHg (40.7±13.3 kPa) or 0.41±0.13 kgf/cm2
Power
AC110~220V ±10%, 50~60 Hz ±1 Hz
Inner NiMH battery: DC12 V
Operation conditions Ambient temperature: 5 to 40, Relative humidity: 20% to 80%
Storage conditions Ambient temperature: -40 to 55, Relative humidity: ≤ 95%
Electric shock protection/class Class I and internal power supply: Type CF, Continuous operation
Water proof level IPX4
Weight 2.25kg (with clamp base)
Dimension 306mm (Width)×135mm (Height)×127mm (Depth)
 
SN-50C6T Syringe Pump
International standard syringe pump
  • Compatible: Automatic syringe calibration, suitable for all brands
  • Convenient: “Openable slider hook”, convenient to clamp syringe plunger
  • Powerful: Battery capable to support more than 6 hours for one channel continuous working
  • Energy saving: Idle channel can be set to sleeping mode
Function
Body weight mode input
Specify syringe size automatically
Identify syringe size automatically
3-level occlusion alarm limits setting
Automatically reduce impact dose release after occlusion
Limits setting
Delivered volume inquiry
KVO flow rate

Operation error prompt
Fast rate control
“Purge” button activate safe protection
Flow rate setting button lock
Abundant optic and sound alarm
AC and internal power indication
Standard RS232 interface
500 history records
 

SPECIFICATION (Single Channel, Body Weight Mode)

Syringes
10, 20, 30, 50 mL of calibrated syringes
Flow rate 0.1-1500 mL/h (0.1 mL/h step) 50 mL syringe
0.1-900 mL/h (0.1 mL/h step) 30 mL syringe
0.1-600 mL/h (0.1 mL/h step) 20 mL syringe
0.1-400 mL/h (0.1 mL/h step) 10 mL syringe
Purge rate 1500 mL/h 50 mL syringe
900 mL/h 30 mL syringe
600 mL/h 20 mL syringe
400 mL/h 10 mL syringe
Accuracy of flow rate
(Nominal value)
Accuracy including syringe: within ±2%
Mechanical accuracy: within ±1%
Display range of volume delivered 0.1–9999 mL
(0.1–999.9 mL,0.1mL step)
(1000–9999 mL,1mL step)
Setting of delivery limit 0.1–9999 mL
(0.1–999.9 mL,0.1mL step)
(1000–9999 mL,1mL step)
Occlusion detection pressure 'H': 800±200 mmHg (106.7±26.7 kPa) or 1.09±0.27 kgf/cm2
'C': 500±100 mmHg (66.7±13.3 kPa) or 0.68±0.13 kgf/cm2
'L': 300±100 mmHg (40.7±13.3 kPa) or 0.41±0.13 kgf/cm2
Power
AC110~220V ±10%, 50~60 Hz ±1 Hz
Inner NiMH battery: DC12 V
Operation conditions Ambient temperature: 5 to 40, Relative humidity: 20% to 80%
Storage conditions Ambient temperature: -40 to 55, Relative humidity: ≤ 95%
Electric shock protection/class Class I and internal power supply: Type CF, Continuous operation
Water proof level IPX4
Weight 2.25kg (with clamp base)
Dimension 306mm (Width)×135mm (Height)×127mm (Depth)
 
SN-50F6 syringe pump

International standard syringe pump

  • Compatible: Automatic syringe calibration, suitable for all brands
  • Convenient: “Openable slider hook”, convenient to clamp syringe plunger
  • Powerful: Battery capable to support more than 6 hours for one channel continuous working
  • Energy saving: Idle channel can be set to sleeping mode.
Function
Dual-channel with different flow rate
Channel sleeping function
Identify syringe size automatically
3-level occlusion alarm limits setting
Limits setting
Automatically reduce impact dose release after occlusion
Delivered volume inquiry
KVO flow rate

Operation error prompt
Fast rate control
"Purge" button activate safe protection
Flow rate setting button lock
Abundant optic and sound alarm
AC and internal power indication
Standard RS232 interface
500 history records
 
SPECIFICATION (Dual Channel)
Syringes
10, 20, 30, 50 mL of calibrated syringes
Flow rate 0.1-1500 mL/h (0.1 mL/h step) 50 mL syringe
0.1-900 mL/h (0.1 mL/h step) 30 mL syringe
0.1-600 mL/h (0.1 mL/h step) 20 mL syringe
0.1-400 mL/h (0.1 mL/h step) 10 mL syringe
Purge rate 1500 mL/h 50 mL syringe
900 mL/h 30 mL syringe
600 mL/h 20 mL syringe
400 mL/h 10 mL syringe
Accuracy of flow rate
(Nominal value)
Accuracy including syringe: within ±2%
Mechanical accuracy: within ±1%
Display range of volume delivered 0.1–9999 mL
(0.1–999.9 mL,0.1mL step)
(1000–9999 mL,1mL step)
Setting of delivery limit 0.1–9999 mL
(0.1–999.9 mL,0.1mL step)
(1000–9999 mL,1mL step)
Occlusion detection pressure 'H': 800±200 mmHg (106.7±26.7 kPa) or 1.09±0.27 kgf/cm2
'C': 500±100 mmHg (66.7±13.3 kPa) or 0.68±0.13 kgf/cm2
'L': 300±100 mmHg (40.7±13.3 kPa) or 0.41±0.13 kgf/cm2
Power
AC110~220V ±10%, 50~60 Hz ±1 Hz
Inner NiMH battery: DC12 V
Operation conditions Ambient temperature: 5 to 40, Relative humidity: 20% to 80%
Storage conditions Ambient temperature: -40 to 55, Relative humidity: ≤ 95%
Electric shock protection/class Class I and internal power supply: Type CF, Continuous operation
Water proof level IPX4
Weight 3.45kg (with clamp base)
Dimension 354mm (Width)×190mm (Height)×128mm (Depth)
 
SN-50T66
International standard syringe pump
  • Compatible: Automatic syringe calibration, suitable for all brands
  • Convenient: “Openable slider hook”, convenient to clamp syringe plunger

Function

Triple channel with different flow rate
Channel sleeping function
Syringe calibrate automatically
Identify syringe size automatically
3-level occlusion alarm limits setting
Automatically reduce impact dose release after occlusion
Limits setting
Delivered volume inquiry
Wireless communication (Optional)

KVO flow rate
Fast rate control
“Purge” button activate safe protection
Flow rate setting button lock
Abundant optic and sound alarm
AC and internal power indication
Standard RS232 interface
500 history records
Operation error prompt
 
SPECIFICATION (Triple Channel)
Syringes
10, 20, 30, 50 mL of calibrated syringes
Flow rate 0.1-1500 mL/h (0.1 mL/h step) 50 mL syringe
0.1-900 mL/h (0.1 mL/h step) 30 mL syringe
0.1-600 mL/h (0.1 mL/h step) 20 mL syringe
0.1-400 mL/h (0.1 mL/h step) 10 mL syringe
Purge rate 1500 mL/h 50 mL syringe
900 mL/h 30 mL syringe
600 mL/h 20 mL syringe
400 mL/h 10 mL syringe
Accuracy of flow rate
(Nominal value)
Accuracy including syringe: within ±2%
Mechanical accuracy: within ±1%
Display range of volume delivered 0.1–9999 mL
(0.1–999.9 mL,0.1mL step)
(1000–9999 mL,1mL step)
Setting of delivery limit 0.1–9999 mL
(0.1–999.9 mL,0.1mL step)
(1000–9999 mL,1mL step)
Occlusion detection pressure 'H': 800±200 mmHg (106.7±26.7 kPa) or 1.09±0.27 kgf/cm2
'C': 500±100 mmHg (66.7±13.3 kPa) or 0.68±0.13 kgf/cm2
'L': 300±100 mmHg (40.7±13.3 kPa) or 0.41±0.13 kgf/cm2
Power
AC110~220V ±10%, 50~60 Hz ±1 Hz
Inner NiMH battery: DC12 V
Operation conditions Ambient temperature: 5 to 40, Relative humidity: 20% to 80%
Storage conditions Ambient temperature: -40 to 55, Relative humidity: ≤ 95%
Electric shock protection/class Class I and internal power supply: Type CF, Continuous operation
Water proof level IPX4
Weight 5.4kg (with clamp base)
Dimension 455mm (Width)×250mm (Height)×139mm (Depth)
 
 
 
Copyrights @ Vital Bio Systems. All rights reserved.
free hit counters