| Finometer Pro |
Optimal accuracy
The Finometer® PRO is a stand-alone solution for accurate non-invasive beat-to-beat blood pressure monitoring. The Finometer® PRO incorporates the patented Modelflow® technology providing hemodynamic parameters such as stroke volume, total peripheral resistance and cardiac output as well as pulse rate (variability) and baroreflex sensitivity analysis. The Finometer® PRO is widely used in clinical settings and advanced scientific research. The absolute accuracy of the Finometer® PRO can be calibrated with an upper arm cuff measurement using the patented Return To Flow (RTF) technology. Recently the Finometer® passed the AAMI/SP10 and BHS protocols*. Optional software offers online monitoring, storage, analysis and review of acquired data. The Finometer® PRO can be used in combination with the optional ECG module. |
|
Stand alone
The Finometer® PRO is the Finapres stand alone solution with the option to export and import data using Beatscope® software. The Finometer® PRO is able to show real time all 15 important hemodynamic parameters. The compact and easy to use design makes the Finometer® PRO very suitable for bedside applications and scientific research. The Finometer® PRO weights about 11 kg (app. 35 lbs.) and has enough storage to record for 24 hours. |
|
|
Accuracy
The Finometer® PRO is designed for optimal accuracy. The technology behind the Finometer® PRO can calibrate the reconstructed blood pressure on set intervals against brachial measurements using an upper arm cuff. The accuracy of the Finometer® findings are reported in numerous articles comparing the Finometer® results with intra-arterial findings*. Furthermore the Finometer® PRO has been validated using the Rica-Rocci Korotkoff method*. The Modelflow® cardiac output has been validated against thermodilution cardiac output in patients undergoing coronary artery bypass surgery**. |
|
Data transfer
The Finometer® PRO provides the option to import and export data to other (statistical) programs for further evaluation and analysis. This makes the Finometer® PRO extremely useful for scientific research. After for example drug admission beat-to-beat hemodynamic parameters can be reviewed. Impact to changing conditions are made clear instantly.
|
|
Overview parameters
The following parameters are available using the Finometer® PRO: |
| |
Parameter |
Abreviation |
| 1 |
Blood Pressure SYS |
SYS |
| 2 |
Blood Pressure DIA |
DIA |
| 3 |
Blood Pressure MEAN |
MEAN |
| 4 |
Heart rate |
HR |
| 5 |
Inter beat interval |
IBI |
| 6 |
Cardiac output |
CO |
| 7 |
Stroke volume |
SV |
| 8 |
Pulse rate variability |
PRV |
| 9 |
Baroreflex sensitivity |
BRS |
| 10 |
Total peripheral resistance |
TPR |
| 11 |
Total arterial compliance |
CwK |
| 12 |
Max. steepness of current upstroke |
dp/dt |
| 13 |
Ascending aortic impedance at DIA |
Zao |
| 14 |
Left ventricular ejection time |
LVET |
| 15 |
Rate pressure product |
PS*HR |
|
| |